IO VOLUME
From BAWiki
Basic Information
Name of Program
IO_VOLUME
Version-Date
3.x / February 2010
Description-Date
February 2010
Catchwords
input for standard visualization software
bathymetry
synoptic dataset
two dimensional(2D), three dimensional(3D)
volume model
universal direct access format
alternative / time dependent bathymetry
UCD format
Tecplot format
Short Description of Functionality
The program io_volume can be used to convert bathymetries and hydrological datasets used in hydro numeric models into formats readable by standard software. The input datasets must be synoptic and have to contain area data (neither profiles nor locations). They can be two dimensional (e.g. waterlevel) or three dimensional (e.g. salinity varying with water depth).
The data model of the converted datasets is called a volume model and contains 3D node coordinates and a 3D connectivity table.
Input-Files
- general input data (file of type io_volume.dat)
- bathymetry of a hydronumerical model (file of type untrim_grid, gitter05.dat or selafin (only bathymetry is evaluated))
- (optional) depth values of the horizontal layers (files of type vertical.dat); depth values contained in the meta data of the datasets overwrite this information
- (optional) synoptic datasets (area, 2D/3D) of a hydronumerical model (files in the universal direct access format see alsodirz.bin or of type netcdf);
Output-Files
The supported ucd format is a format mainly used by AVS/Express. Compared with the classic UCD format it can contain time dependent data.
- (optional) bathymetry as a surface (2D) ( file of type ucd or tecplot; if a time dependent bathymetry is given, this file will have time dependent values)
- (optional) bathymetry as a spatial body (3D) ( file of type ucd or tecplot)
- (optional) hydrological data as a surface (2D physical measures) ( file of type ucd or tecplot )
- (optional) hydrological data as a spatial body (3D physical measures) ( file of type ucd or tecplot )
- (optional) lineprinter file containing useful information related to program execution (filetype io_volume.sdr);
Methodology
Program(s) to run before this Program
DATACONVERT, DIDASPLIT, SEDIMORPH, TELEMAC-2D, TM2DIDA, TR2DIDA, TR3DIDA, UNTRIM, UNTRIM2007
Program(s) to run after this Program
AVS/Express (ungetestet), TECPLOT
Additional Information
Language
Fortran90
Additional software
-
Original Version
Maintenance
Documentation/Literature
$PROGHOME/examples/io_volume/
back to Program Descriptions