Actions

INSPECT CONTROL VOLUMES: Difference between revisions

From BAWiki

imported>Spohr Susanne
(Version 1.1: ASCII output)
imported>Spohr Susanne
(Verarbeitung aggregierte integrale Transport aus SediMorph)
Line 2: Line 2:
|name_de=INSPECT_CONTROL_VOLUMES
|name_de=INSPECT_CONTROL_VOLUMES
|name=inspect_control_volumes
|name=inspect_control_volumes
|version=1.1 / October 2015
|version=1.3 / March 2016
|version_descr=October 2015
|version_descr=March 2016
|catchwords=
|catchwords=
data analysis<br />
data analysis<br />
Line 30: Line 30:
* salt transport
* salt transport
* heat transport
* heat transport
* tracer transport (fraktioniert)
* tracer transport (fractionated)
* suspended sediment transport (fraktioniert)
* suspended sediment transport (fractionated)
* sediment transport ([[Mathematical Model SEDIMORPH|SEDIMORPH]]-Output, fractionated)
<br />
<br />
The German-language website offers further information about the content
The German-language website offers further information about the content
of the individual charts.
of the individual charts.
Line 45: Line 44:


|methodology=
|methodology=
The volume flux in a time step can be calculated in two independent ways:
The volume flux or mass flux in a time step can be calculated in two independent ways:
* Way 1: From the transport volume (V) the change (dV / dt) can be determined for each time step.
* Way 1: From the transport volume '''''V''''' or transport mass '''''M''''' the change ('''''dV/dt''''' or '''''dM/dt''''' ) can be determined for each time step.
* Way 2: By addition:
* Way 2: By addition:
*# of the fluxes through the exchanges of the control volume (CV),
*# of the fluxes through the exchanges of the control volume (CV),
Line 52: Line 51:
*# plus an exchange through surface and ground of the CV.
*# plus an exchange through surface and ground of the CV.


The determined volume fluxes will usually not match exactly.
The determined volume fluxes or mass fluxes will usually not match exactly.
The application calculates the time series both for the absolute and the relative error.<br />
The application calculates the time series both for the absolute and the relative error.<br />
The table shows the mean, minimum and maximum values of these two variables.
The table shows the mean, minimum and maximum values of these two variables.

Revision as of 10:25, 14 March 2016

Basic Information

Name of Program

inspect_control_volumes

Version-Date

1.3 / March 2016

Description-Date

March 2016

Catchwords

data analysis
synoptic data sets
aggregated data for control volumes
visualization of time series
CF NetCDF format
MATLAB

Acknowledgment: This project took advantage of netCDF software developed by UCAR/Unidata (www.unidata.ucar.edu/software/netcdf/).

Short Description of Functionality

The application allows the visualization and inspection of the synoptic, aggregated transport quantities, calculated by the program NCAGGREGATE. The data are available either for exchanges or for control volumes.

The quantities for the currently set tranport type will be shown for the selected control volume. Fractional quantities are shown class-wise. The presentation period may be restricted by the user. The output of the time series in a text file is possible.

Picture GUI of application inspect_control_volumes.

Possible transport types:

  • water transport
  • salt transport
  • heat transport
  • tracer transport (fractionated)
  • suspended sediment transport (fractionated)
  • sediment transport (SEDIMORPH-Output, fractionated)


The German-language website offers further information about the content of the individual charts.

Input-Files

  1. Aggregated Data format (cf-netcdf.nc).

Output-Files

  1. optional output of the time series in an ASCII file.

Methodology

The volume flux or mass flux in a time step can be calculated in two independent ways:

  • Way 1: From the transport volume V or transport mass M the change (dV/dt or dM/dt ) can be determined for each time step.
  • Way 2: By addition:
    1. of the fluxes through the exchanges of the control volume (CV),
    2. plus intake and outtake of sources and sinks of the CV,
    3. plus an exchange through surface and ground of the CV.

The determined volume fluxes or mass fluxes will usually not match exactly. The application calculates the time series both for the absolute and the relative error.
The table shows the mean, minimum and maximum values of these two variables.

Program(s) to run before this Program

NCAGGREGATE

Program(s) to run after this Program

none

Additional Information

Language

MATLAB

Additional software

Linux: MATLAB Compiler Runtime MCR R2015a in directory /usr/local/MATLAB/R2015a

Original Version

S. Spohr

Maintenance

S. Spohr

Documentation/Literature

None. See also under MATLAB.


back to Program Descriptions