Actions

RNDWERTE.DAT: Difference between revisions

From BAWiki

imported>BAWiki 2
(Created page with '{{FileDescription |name_de=RNDWERTE.DAT |filetype=rndwerte.dat |version=January 1996 |version_descr=January 1996 |significance=contains informations about types and values of …')
 
mNo edit summary
 
Line 3: Line 3:
|filetype=rndwerte.dat  
|filetype=rndwerte.dat  
|version=January 1996  
|version=January 1996  
|version_descr=January 1996
|version_descr=August 2023
|significance=contains informations about types and values of boundary conditions for various numerical models  
|significance=contains informations about types and values of boundary conditions for various numerical models  
|filecontents=
|filecontents=
Line 26: Line 26:
## linear interpolation between data points
## linear interpolation between data points
## cubic spline-interpolation between data points
## cubic spline-interpolation between data points
# scaling factors for the generated time-series
# scaling factors for the generated time-series. Important when implementing time series of the fresh water discharge, because in this case the factor is the reciprocal of the overall width of all edges of the fresh water discharge inflow (or outflow). Example: The discharge of the river Ems will flow over two grid edges into the model domain and each grid edge has a length of 15 m. The overall width ist 30 m and the factor given in the file has to be 1/30 /m.
# time-series information and/or input data
# time-series information and/or input data
|nutzerprogramme=
|nutzerprogramme=

Latest revision as of 09:17, 14 August 2023

Basic Information

File-Type

rndwerte.dat

File-Form

FORMATTED

Version

January 1996

Description-Date

August 2023

Significance of the File

contains informations about types and values of boundary conditions for various numerical models

File-Contents (in Catchwords)

  1. number of different time-series for boundary nodes
  2. time interval
  3. type of boundary condition
    1. specific flowrate in x-direction
    2. specific flowrate in y-direction
    3. water elevation
    4. salinity
    5. water elevation (for interior nodes, TRIM-2D/TRIM-3D)
    6. temperature
    7. heat content
    8. suspended sediment concentration
    9. suspended load
    10. height of a weir (U-node, TRIM-2D)
    11. height of a weir (V-node, TRIM-2D)
    12. velocity in x-direction
    13. velocity in y-direction
  4. different generation processes for the time-series
    1. sum of multiple cosine-functions
    2. linear interpolation between data points
    3. cubic spline-interpolation between data points
  5. scaling factors for the generated time-series. Important when implementing time series of the fresh water discharge, because in this case the factor is the reciprocal of the overall width of all edges of the fresh water discharge inflow (or outflow). Example: The discharge of the river Ems will flow over two grid edges into the model domain and each grid edge has a length of 15 m. The overall width ist 30 m and the factor given in the file has to be 1/30 /m.
  6. time-series information and/or input data

Programs using this Type of File

TICTRI, TM2RND, TR2RND, UTRRND

Example-File

$PROGHOME/examples/tm2rnd/rndwerte.dat (for TELEMAC-2D)


back to: File Descriptions


Overview